2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Galvanic Corrosion and Red Plague

Testing & Assessment

Key Takeaways
  • Red Plague is a term that refers to a specific type of silver-plated copper corrosion.
  • Some wire/cable manufacturers have found a way to minimize the likelihood of red plague.
  • There is an industry accepted method for measuring key factors in a wire’s red plague susceptibility.

Any concept that has earned the word “plague” in its name is certain to be an infamous hassle. The “Red Plague” of the aerospace industry is no exception. For decades, the plague has been identified with corrosion impacting the performance of silver-plated copper conductors.

Some have brushed the issue aside saying that they have never seen it, thus it is not a problem. To put the issue of red plague into perspective, a worst-case estimate suggests as much as 3% of braided silver-plated copper shields have some degree of red plague. Across the aerospace industry, this equates to millions of dollars each year in scraped products, rewiring, and maintenance actions.

This article provides an overview of the subject and a means to determine susceptibility.

Galvanic Corrosion

Corrosion is the chemical process that converts a refined metal to a more stable form, such as its oxide or hydroxide. Galvanic corrosion is an electrochemical process induced when two dissimilar materials are coupled in an electrolyte that promotes corrosion (the same process used in batteries, which rely on galvanic corrosion to generate voltage). The galvanic corrosion of silver-plated copper conductor, often insulated by ETFE and other fluoropolymers, is generally known as Red Plague.

Dissimilar Metals
Contact between dissimilar metals can results in rapid corrosion. This chart shows the compatibility of several common aircraft metals. . Source FAA.

Not a New Problem

Red plague is not a new concern in the aviation and wiring industries. In fact, the issue pre-dated the original March 1965 article, penned by P.L. Anthony and O.M. Brown, which examined causes and outlined conditions for Red Plague evolution. The Red Plague, when visually observed on corroded wires, is identified by either a red or black tarnish, where the red is the cuprous oxide (Cu2O) and the cupric oxide (CuO) appearing black. Silver plating of the copper alloy wire strands inhibits corrosion, although production flaws, handling, environmental factors, and application conditions can alone, or in concert, defeat the inhibition of corrosion.

Getting to the Core

A recent concern regarding Red Plague evolution is the destruction of the copper core can occur when the conductor’s silver-plating is intact and of sufficient thickness (>40 µin). The first possible culprit of the corrosion was water. Water is used to cool wires during the production process and some aircraft operate in very humid environments. The ingress and depositing of water can happen through wicking from unprotected and exposed connectors or through the condensation during thermal cycling. However, it is not possible for water molecules to diffuse through the silver layer, nor is the silver susceptible to oxidation or corrosion in moist air.

The search for the corrosion promoter then went looking into the wire insulation constructions. Some fluoropolymer insulations are known to off-gas. Of interest were the wire insulation types that off-gas fluorine. This fluorine could react with the water molecules to form hydrofluoric acid. This acid weakens the silver plating, forming pores allowing water to corrode the copper core. In their 2010 Red Plague control plan, NASA identified protecting wire from high humidity air as a significant mitigation technique and suggested that all aqueous exposure be eliminated.

How thick is thick enough?

As such, while making the silver plating thicker can provide some benefit, the wire/cable insulation and jacket material performance hold an important role element in preventing the corrosion. Each manufacturer has a different process for making and curing their insulation, and it is this variability that creates the problem with some manufacturers and not with others. The process control has a significant impact on the off-gassed fluorine concentration.

Off-gassing is something that may not be fully eliminated from these problematic insulation types, but research has shown that <20ppm is unlikely to produce red plague on silver-plated samples.

What is Susceptible to Red Plague?

To help combat the plague, Lectromec employs Fluorine Evolution testing of fluoropolymer insulations to help our clients determine if a wire/cable is prone to promote Red Plague. The test evaluates the off-gassing of fluorine from the insulation in the absence of conductor material. This method measures the concentration of fluorine dissolved in pure water and compare the measured electrical conductivity to the control. The greater the concentration of fluorine dissolved into the aliquot, the greater the build-up of opportunistic corrosive products on the silver plating that promote corrosion of the copper alloy that lies beneath.

Devon Gonteski

Devon Gonteski

Engineer, Lectromec