2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

The development and use of coaxial cables have come a long way since its invention in 1880. Improvements in design and reliability have made it a frequent feature for aircraft data transmission applications. In the realm of aerospace, a common coaxial specification is the MIL-DTL-17 coaxial cable standard.

There are several parts to the MIL-DTL-17 (currently at revision H) standard of which application engineers and EWIS designers should be aware. Certainly, the requirements of coaxial cables have evolved as the needs of airborne applications have changed (the military Assist website only have revisions dating back to 1983, and this is revision F). This article provides information on what the cables in this standard are, and characteristics that you should be aware of when selecting or maintaining these cables.

Overview

coaxial cable breakdown
Example coaxial cable.

The MIL-DTL-17 standard covers signal cables specifically designed for “low-loss, stable operation from the relatively low frequencies through the higher frequencies in the microwave and radar regions of the frequency spectrum.” (note: for those unfamiliar with cable specifications, there is typically a based standard, such as MIL-DTL-17, that contains general information, then there are ‘slash sheets’, which are specific cable constructions that fall into the generalized category of the base standard). Specifications, such as the MIL-C-17/185C, are recommended for use up to 1GHz. Whatever the particular use might be, the typical construction of the coaxial cable is the following:

  • Jacket: The cable jacket is the outside most surface of the coaxial cable. The jacket is typically made of a tough, flexible, and non-hygroscopic material. There are several material types that are specified in MIL-DTL-17 which include: PVC, Neoprene, Silicone impregnated fiberglass, PTFE, FEP, ETFE, PFA, Polyolefin. The use of the particular jacketing material should be based on environmental and mechanical conditions on the aircraft.
  • Shield: The shield is immediately under the cable jacket and is a conductive layer for EMI protection. The shielding is further discussed in the following section.
  • Dielectric Core: The dielectric core is used to maintain a consistent dielectric material between the inner conductor and the shield. The consistent shape and uniformity of the dielectric core material is important for stability of the electrical signals carried in the cable. As one might suspect, there are several types of approved dielectric cores in MIL-DTL-17. Many of the modern slash sheets for the MIL-DTL-17 specification use an air-spaced polyethylene material as the dielectric core.
  • Conductor: This core conductor is the primary signal carrier for the cable. Depending on the particular MIL-DTL-17 slash sheet selected, the conductor can be made of any one of several permitted conductor types ranging from bare copper to annealed copper-clad steel wire.

Shielding

As discussed earlier, the primary reason for these cables is for signal transmission. This might be for data between devices in the aircraft or for signal antennas. Either way, proper shielding of the cables ensures good system performance. Past Lectromec articles on shielding for cables have covered the different types of shielding and the potential impacts of EMI.

Flammability

An interesting item about the MIL-DTL-17 cables is that flammability, while it has been in the standard for several iterations, has not always been a requirement of the standard until now. Several of the coaxial cables in the standard, such as MIL-C-17/77 and MIL-C-17/78 do not have flammability requirement (note: these are now inactive standards, but they can still be found on aircraft). For those using these cables, it is advised to consider the risk associated with these cables and determine if a replacement is necessary at the next opportunity.

The flammability test that is called out for in the MIL-DTL-17 is the same 60o burn test as identified in other standards (more can be read here).

Impedance Matching

One item to note with these cables is that, as with any signal cable, impedance matching is very important. For those unfamiliar with impedance matching, anytime there is a break in the circuit, such as at connection devices, the impedance of the mating, if not done properly, can have a significant impact on the signal strength. Slight impedance changes can dissipate the signal energy or reflect it and reduce the overall signal strength to the target device. Identification of these circuit interrupts can be done with Time Domain Reflectometry (TDR) technologies.

This long aside has been made for the purpose of highlighting the importance of selecting cables that match the impedance of the application and not using just whatever is convenient or cheaper. Not all cables are the same and care should be taken when evaluating which cable to use for aircraft design.

Verification Tests

As with any aerospace cable, there are a lot of qualification and verification tests necessary for acceptance and many of these tests are the same as the standard single conductor wires. The following is a brief list of common qualification tests performed on coaxial cables:

Application Notes

When using these materials, there are several limitations:

  • Flexibility: most of the coaxial cables are not designed for regular flexing applications as a change in the cable shape can impact signal quality
  • Limited temperature range: Whereas may of the AS22759 family of wires are rated to 150C and above, 85C is a common threshold temperature for these cables. As such, the possible applications are limited, particularly near engines.
  • Maintainability: Coaxial cables have historically been a challenge for repair on aircraft. The dielectric must be repaired with great care and the shield rejoined such that there is no change in the electrical properties. There are coaxial splices and repair tools available, but practice is necessary to ensure the splice is performed correctly.

Summary

Coaxial cables are a critical part of the EWIS design and will continue to be for quite some time. The selection and use of coaxial cables for each application should be carefully considered as there are a lot of choices and it is important to pick the correct one. If you have a need for guidance on part selection, EWIS certification, or EWIS component testing, contact Lectromec.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than a decade. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. In September 2014, Michael was appointed as an FAA DER with a delegated authority covering EWIS certification.