2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code
Key Takeaways
  • Installed EWIS should be able to be be inspected, tested, repaired, and, if necessary, replaced with a minimum of aircraft disassembly and without causing undue disturbance to the EWIS installation or to surrounding aircraft systems.
  • Wiring and other EWIS components are vulnerable to potential damage during inspection and maintenance.
  • Industry guidance exists to ensure both safety and accessibility for EWIS inpection and maintenance.

Wiring, like many other parts on an aircraft, should be blocked from access for much of its service life. It is only during maintenance, inspection, or repair that are panels removed, equipment uninstalled, and access ports opened to reveal the wiring. Even with all equipment and panels removed, certain locations of each aircraft can be difficult to access/inspect. To that end, this article reviews the regulatory requirements, industry standards, and practical factors that play into the accessibility of an aircraft’s EWIS.

Regulation

Perhaps the most logical starting point is to look at the regulations. The FAA regulation for EWIS Accessibility, § 25.1719, states:

“Access must be provided to allow inspection and replacement of any EWIS component as necessary for continued airworthiness.”

The wording of the EASA version of this regulation is almost identical:

“Means must be provided to allow for inspection of EWIS and the replacement of its components as necessary for continued airworthiness.”

Intent

The regulation’s intent is to ensure that the installed EWIS can be inspected, tested, repaired, and, if necessary, replaced with a minimum of aircraft disassembly and without causing undue disturbance to the EWIS installation or to surrounding aircraft systems. A common outcome of wiring maintenance is unintended damage due to contamination (introduction of FOD (Foreign Object Debris) into connectors, fluid contamination, the introduction of swarf and other FOD into wire bundles where it can cause wire/cable damage), chafing, and other types of damage.

Among the goals of these regulations is the aim to impact the EWIS design phase such that designers minimize the amount of aircraft disassembly required to perform tasks that require EWIS access. For example, the wiring inside conduit may incur damage from chafing against the sides of the conduit. If failure of wiring inside a conduit can lead to an unsafe condition, a means should be provided for inspection and, if necessary, replacement of those wires. Inspection may be by testing (such as insulation resistance, DVW (Dielectric Voltage Withstand), TDR (Time Domain Reflectometry), etc.) or other acceptable inspection techniques and should be included in the maintenance requirements with ICAs (Instructions for Continued Airworthiness).

It is important here to recognize the language of the regulation in that “access must be provided to allow for inspection and replacement…”. Ideally, replacement will not require days of equipment removal, but that determination is up to the designer (tools like the EWIS RAT (Risk Assessment Tool) can be used to determine the failure probability of a wire harness, system’s EWIS, etc.). Naturally, if a wire harness is in such an installation condition, the design should be robust to minimize the chances of degradation and damage (connectors rated for a high number of demate/mate cycles, additional physical protection on harnesses, robust clamps, etc.).

Levels of Inspection

From accessibility for inspection, the requirements for visual inspection are a good place to start; the guidance that was provided to support EZAP (Enhanced Zonal Analysis Procedure) helps to fill this gap. The GVI, or General visual inspection, is defined in AC 25-27A:

“A GVI is defined as a visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance of the inspected object unless otherwise specified. It is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors.

It may be necessary to use a mirror to improve visual access to all exposed surfaces in the inspection area. Stands, ladders, or platforms may be required to gain proximity to the area being checked.

It is expected that the area to be inspected is clean enough to minimize the possibility that accumulated dirt, grease, or other contaminants might hide unsatisfactory conditions that would otherwise be obvious.”

And a Detailed Visual Inspection (DET)

“DET is an intensive examination of a specific item, installation, or assembly to detect damage, failure, or irregularity. Available lighting is normally supplemented with a direct source of good lighting at an intensity considered appropriate. Inspection aids, such as mirrors, magnifying lenses, or other means, may be necessary. Surface cleaning and elaborate access procedures may be required. A DET can be more than just a visual inspection. It may include tactile assessment to check a component or assembly for tightness and security. Such an inspection may be needed to ensure the continued integrity of installations such as bonding jumpers, terminal connectors, etc.

A DET would be required when the developer of the EZAP determines that a GVI is inadequate to reliably detect anomalies or degradation of EWIS components.”

Attenuation Test Setup
Example of wire accessibility on aircraft.

Wherever possible, designers should seek to make it possible for the aircraft EWIS to be inspected visually at the DET level, but practical limitations will inhibit this…and that can be acceptable. One item not discussed in the inspection levels is the system criticality which is a driver of inspection type used. Wiring for more critical systems will tend to require DET inspections. That said, if an area of an aircraft is less accessible, and it is at all possible, routing wiring with lower system criticality through these areas is recommended.

Alternatives to Visual Inspection

If visual inspection cannot be accomplished, then assessments must be done to determine the likely failure modes and if alternative condition assessment techniques will be sufficient. For example, the primary and redundant wiring to a system are installation locations precluding visual inspection. The following factors should be considered for these installations:

  • What is the probability of failure of these circuits, and what is the probability of failure within the uninspectable areas?
  • What are the physical failure consequences of each circuit?
  • What are the functional failure consequences of each circuit?
  • Is there the possibility of a single failure causing the loss of both circuits?
  • Is a latent fault possible in the uninspectable areas?
  • What changes to the system/installation would be necessary to support the non-visual inspection techniques (e.g., will it be necessary to have easy access to demate the connectors at both ends of the circuit and enough physical space to connect the connectors to automatic wire testing systems)?

Considering each of these questions should help to guide the frequency and type of inspection. The non-visual inspection types

Conclusion

Physical access to all parts of an aircraft’s wiring system is a non-trivial task that is necessary for compliance with regulations and requires attention to detail. While many of the issues may be identifiable within aircraft models, the final determination of what is inspectable cannot be made until an inspector is physically able to enter an aircraft and shine a flashlight on the wire bundles. There are specific requirements for general visual inspection (GVIs) and Detailed Visual Inspection (DETs), and they should be considered when reviewing a design.

To find out more about how Lectromec can help support your aircraft’s design and certification, contact us at any time.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than a decade. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. Michael is an FAA DER with a delegated authority covering EWIS certification and the chairman of the SAE AE-8A EWIS installation committee.