2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Archives

Dynamic Cut Through

One of the most common means for damage to a wire/cable on an aircraft is when the wire/cable is crushed. This may happen by a misaligned LRU, accidental contact by maintenance, or any other way that a wire/cable may be pinched when in-service. A wire/cable’s ability to withstand compression damage, particularly at elevated temperatures, will […] Read more

Dielectric Withstand Voltage

The dielectric withstand voltage (DWV), sometimes referred to as the “Voltage Proof Test” or “Wet Dielectric Test”, is perhaps one of the most referenced tests when examining wires. The reason is that the test performs the most important part in wire insulation assessment: it determines if the wire insulation is free of breaches (or has […] Read more

Forced Hydrolysis

The forced hydrolysis test places the wire/cable specimen in a high-temperature water bath for an extended duration to evaluate the durability of a wire insulation in high-humidity conditions. Depending on the particular wire specification needs, the test may be required to run for thousands of hours. After the prolonged exposure, the sample is then examined […] Read more

Blocking

This test evaluates if a finished wire/cable specimen will block (stick to itself) when subjected to the specimen’s rated temperature. While on an aircraft, wires may be exposed to high temperatures and it is important to check if the finished wire specimens are prone to blocking (in other words, the test examines whether the wire […] Read more

Overload Resistance – Smoke Resistance

In short circuit conditions, a circuit may run over the designated current for an extended duration before the circuit protection is activated. During this time, a wire/cable may become very hot and potentially exceed its designated thermal rating. Well designed wires/cables will not release any smoke during this fault condition. The overload resistance test, also […] Read more

Capacitance per Unit Length 

Sometimes referred to as the Dielectric Constant, the capacitance of a wire/cable is of particular interest for data applications (limited importance for power applications). Those wires/cables with high capacitance values can significantly impact signal quality, particularly high speed data applications. This test, which can be performed on a wire or cable, measures the specimen’s capacitance […] Read more

Conductor Diameter

Also referred to as the wire size test, this evaluation measures the sample’s conductor diameter after the insulation has been removed. This test method is important for identifying the proper amount of conductor used for a particular gauge. Verifying that the supplied wire has not been misrepresented. The test report includes the measured conductor diameter […] Read more

Conductor Resistance

This test determines a conductor’s direct current (DC) resistance at a specified reference temperature (typically set at ambient temperature). There are two methods used to conduct this test known as the Kelvin Bridge Method and the Wheatstone Bridge Method, which are used to obtain the resistance of the specimen. Both methods will give similar results, […] Read more

Cable to Cable Abrasion

This test is used to determine the ability of a sample’s insulation to withstand the rubbing on a similar sample in a vibrational environment. Wires/cables in close contact with one another can rub against each other causing progressive deterioration of the insulation. The impact of how quickly the insulation degrades in a wire-to-wire scenario is […] Read more

Scrape Abrasion

One of the most common means for wire failure is through insulation chafing. In operating conditions, wires/cables are exposed to various sharp edges on aircraft that can quickly deteriorate the insulation integrity. This test assesses the wire/cable’s insulation durability to sharp edges at ambient temperature. The sample is abraded until failure. The failure is identified […] Read more