View Latest Blog Entries
Close
Categories
Testing & Assessment Standard & Regulation Certification Aging Wires & Systems Maintenance & Sustainment Protection & Prevention Management Conference & Report Research Miscellaneous Arcing
Popular Tags
Visual Inspection High Voltage AS50881 MIL-HDBK MIL-HDBK-525 FAR Electromagnetic Interference (EMI) Maintenance AS4373 FAR 25.1707 Degradation Wire System
All Tags in Alphabetical Order
2021 25.1701 25.1703 3D print abrasion AC 120-102 AC 33.4-3 AC 43 Accelerated Aging accessibility Additive Manufacturing ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS39029 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard AS9102 ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ASTM-B33 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing characteristic impedance Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Completed Harness Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector contacts Connector Durability Connector Failure Modes connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage Custom component D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Firewall First Article Inspection Fixturing Flame Resistance Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook harness construction Harness Design harness installation harness protection harness testing hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation High Voltage Systems HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion impedance insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 6722 ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-22992 MIL-DTL-23053E MIL-DTL-32630 MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-HDBK-863 MIL-M-24041 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE polyurethane Potting Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through PWM quadrax Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability removable contact Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee SAE J1127 SAE J1128 Sanitizing Fluids schematic Scrape Abrasion Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable signal reflection Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 WAIC wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification Wireless wiring components wiring diagram work unit code

First-Article Testing of Wire Harnesses

Testing & Assessment

Key Takeaways
  • First-article testing of wire harnesses is a layered system-level verification plan often unique to the harness under test.
  • Wiring harness first-article plans usually adapt existing wire, cable, and connector tests rather than invent new harness-specific methods.
  • The most effective sequence starts with low-energy verification, then adds higher electrical stress, environmental or application-specific stresses, and finally repeats the core electrical checks.

Executive Summary

First-article testing of a wire harness is not a single prescribed test; it is a three-layer system-level verification plan that relies on:

  • A first article documentation framework
  • An assembly workmanship/acceptance framework,
  • A set of inherited test methods adapted to evaluate the completed harness.

For aerospace, AS9102C defines how first-article inspections are to be performed and documented. Because the AS9102 is generalized, the specific means of assessment requires implementers to source technical content from standards such as IPC/WHMA-A-620F, NASA-STD-8739.4A, MIL-DTL-3885H, AS4373, etc.

Standards and Test Basis

In practice, first-article paperwork usually starts with SAE International AS9102C, workmanship and acceptance with IPC and the Wire Harness Manufacturers Association in IPC/WHMA-A-620F, mission-workmanship requirements from NASA (NASA-STD-8739.4a), military cable-assembly baselines, and component performance requirements. The AS9102C establishes how FAI (First-Article Inspection) is performed and documented, while IPC/WHMA-A-620F supplies the main consensus acceptance standard for cable and wire harness assemblies. Where uncommon or specialized designs are needed, custom acceptance criteria may need to be implemented.

The key is that harness first-article plans usually adapt existing wire, cable, and connector tests rather than invent new harness-only methods. Standards such as AS4373, ASTM D3032, and EIA-364 are often used for this purpose. AS4373 is a general aerospace wire test-method standard, ASTM D3032 explicitly applies not only to single insulated conductors but also to assemblies such as cable bundles and harnesses, and EIA-364 test methods are connector tests that can be adapted to meet harness requirements. In other words, the completed harness is tested as the place where all of those inherited component assumptions meet, or where the reduced engineering margins are verified.

What a Harness FAI Should Actually Measure

A rigorous harness FAI uses the completed assembly as the unit under test, but the test logic still comes from inherited component methods.

Pin-to-pin continuity (Low Voltage Testing). The purpose is to verify the connections, detect opens, miswires, reversals, and establish whether contact-plus-conductor resistance is acceptable. Typical practice is to use fixture-based automated analyzers with mating interfaces rather than direct probing; NASA explicitly prohibits the use of hand probes directly in harness connectors, and commercial harness analyzers routinely document continuity, resistance, miswires, and isolation. Acceptance criteria are usually drawing- or program-specific; for example, NASA requires point-to-point continuity but does not assign a universal ohmic limit.

Circuit isolation, hipot, and insulation resistance. Separate from pin-to-pin continuity, the circuit isolation tests seek to determine if there is sufficient physical separation between conductors. The NASA-STD-8739.4A gives a complete acceptance sequence and acceptance values: continuity first, then dielectric-withstanding-voltage (DWV) , then insulation resistance (IR).

  • DWV is 1050 ± 50 Vrms at 60 Hz or 1500 ± 75 Vdc, or the lower value defined by the connector/cable/wire datasheet; dwell is at least 5 seconds with a ramp rate of at least 500 V/s; leakage current must not exceed 1 mA;
  • IR is measured at 500 Vdc until stabilized, not exceeding 1 minute, with a minimum of 100 MΩ.

The AS9102 and IPC do not provide universal voltages, so customer requirements or the lowest-rated component will dictate the applied voltage on a circuit. Common failure modes that are detected with this testing include:

  • Nicked insulation
  • Stray wire strands
  • Conductive contamination
  • Inadequate spacing
  • Shield termination issue

If a test article fails here, the cause is usually workmanship based.

Moisture proofness. Moisture testing matters whenever the harness contains rear seals, overmolds, potted transitions, solder sleeves, splices, boots, or material that could wick fluids. The procedure typically consists of multiple steps that include:

  • Continuity/IR/DWV,
  • Humidity cycling or direct immersion,
  • Post-exposure electrical retest and visual inspection.

MIL-STD-202 Method 106 provides a cyclic moisture-resistance basis, and Method 104 (Immersion) is often used because immersion will aggravate incipient defects in seals. Acceptance criteria are commonly post-exposure measurements of continuity, IR, and hipot plus no visible ingress, corrosion, swelling, or seal displacement. Typical failures include rear-seal leakage, wicking through splices, corrosion at shield terminations, and overmold voids. In FAI, those results usually drive changes in sealing architecture and potentially process tweaks.

Partial discharge for high-voltage harnesses. For HV harnesses, continuity and hipot are necessary but not sufficient. IEC 60270 defines the charge-based Partial Discharge (PD) measurement methodology for components and systems. In practice, the voltage is increased until PD starts, then reduced until it extinguishes (PDIV (Partial Discharge Inception Voltage) and PDEV (Partial Discharge Extinction Voltage), respectively). When performed, the harness PD performance can be impacted by the system level factors and installation environment. Factors such as altitude, voltage waveform, and temperature, all influence the test results. Acceptance criteria are usually program-specific rather than standards-generic. A sound engineering rule is that PDEV should remain above maximum operating voltage with margin; otherwise, discharge initiated by a voltage transient can continue in service.

The common failure modes detected with the PD testing are voids in potting compound, sharp field concentrations, contamination, inadequate creepage/clearance, and pressure-sensitive connector interfaces (most of these issues are at or near the terminations). Those are precisely the defects that a harness FAI should aim to expose before production.

Shield effectiveness. Shielding is one of the most frequently over-simplified parts of a harness FAI. IEC 62153-4-3, -4-7, and -4-15 are usually more relevant at the harness level because they address transfer impedance, screening attenuation, and coupling attenuation of cable shields, mated screened connectors, and cable assemblies. If the question is system susceptibility rather than direct attenuation, ISO 11452-4 and SAE J1113/4 provide BCI (bulk current injection) methods that couple RF (radio frequency) onto the harness itself.

The acceptance criteria for shield effectiveness are (again) program-specific. Frequent failure modes detected with these tests are bad pigtail terminations, poor shell bonding, braid discontinuities, high backshell-to-shell resistance, and weak connector transitions. Design teams often discover here that a cable that looked “shielded” on paper became a poor shield after termination.

Thermal Cycling. The purpose of thermal cycling in harness FAI is to force differential expansion and contraction across components. Typical aerospace and military harness FAIs do not use a single harmonized profile; instead, specifications like EIA-364-32 thermal shock/temperature for connectors can be modified for harness test needs. These thermal cycling test will typically have 5 stages:

  • Heat up
  • Dwell at high target temperature until the entire system reaches thermal equilibrium
  • Move to ambient conditions or to a low temperature freezer.
  • Dwell at low target temperature until the entire system reaches thermal equilibrium.
  • Rest at ambient then repeat or repeat immediately.

Thermal performance under load. Thermal FAI is most useful on power harnesses, tightly bundled routes, and connector-dense assemblies. Connector standards assess current-carrying capacity through temperature-rise and current-temperature-derating tests, and that logic adapts well to harnesses. For FAI testing, this should seek to apply worst-case simultaneous currents, instrument the highest-risk regions, wait for stabilization, and then repeat electrical checks and measure voltage drop.

The maximum allowable temperature rise is usually dictated by a combination of factors that include component limits, operational ambient temperature derating, and derating for safety. The most revealing locations for temperature monitoring are contact interfaces, splice bodies, branches within dense bundle cores, and backshell exits. Common failures found with this test method are hot contacts, undersized wire, unbalanced current paths, and local overheating near sleeving or seals. These are split between design and manufacturing issues, not merely test anomalies.

FAI requires consideration of several steps, starting from low-energy verification and proceeding to higher-stress, often application-specific, evaluations.

Recommended First-Article Sequence

The most effective sequence starts with low-energy verification, then adds higher electrical stress, environmental or application-specific stresses, and finally repeats the core electrical checks. That sequencing is consistent with NASA’s continuity → DWV → IR order and with the broader AS9102 principle that first article results must remain traceable back to the specific assembly tested.

Conclusion

The practical implication is straightforward: a credible harness FAI is rarely just a continuity check. Electrically, a starting point is pin-to-pin continuity (voltage drop) along with circuit isolation, dielectric withstand, and insulation resistance. If the harness contains sealed interfaces, overmolds, boots, splices, or operates in moisture-prone environments, assessment of moisture proofness becomes essential. Harnesses designated for high-voltage applications should consider partial discharge evaluations under representative altitude and temperature conditions. Shielded harnesses often warrant transfer-impedance, coupling-attenuation, or bulk-current-injection work, and high-current or tightly bundled harnesses may need thermal loading on worst-case simultaneous circuits. The common thread is that harness FAIs usually adapt existing component-level tests to the finished assembly and its actual geometry.

Lectromec’s ISO 17025 accredited lab is well positioned for harness first-article testing and plan development. Our experience supporting the entire EWIS supply chain makes it possible to address all of your FAI test needs in a single location. Those interested in learning more, contact Lectromec.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in the field of EWIS for more than two decades and has worked on a wide range of projects from basic component testing, aircraft certification, and remaining service life assessments. Michael is an FAA DER with a delegated authority covering EWIS certification, the former chairman of the SAE AE-8A EWIS installation committee, and current vice chairman of the SAE AE-8D Wire and Cable standards committee.