2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code
Key Takeaways
  • Clearance distance is the minimum separation distance between two conductive parts in air based on the shortest line of sight between two conductive parts.
  • Creepage distance is the minimum separation distance of two conductive parts along the surface of a solid insulating material.
  • Factors including voltage, altitude, pollution, and insulation materials all affect creepage and clearance distances.

High voltage systems on aircraft will be more commonplace as the eVTOL market “takes-off.” One safety aspect that often comes up is the separation of the high voltage; often, this comes down to creepage and clearance distance of these systems. These distances are used on static conductive points on surfaces and come with the following limitations:

  1. These are not representative of separation distances in volumes other than air.
  2. Creepage and clearance should not be used to identify the safe separation distance of EWIS components in the instance of an arcing event; SAE AIR 6982 (which is in draft stage) will provide guidance on safe separation testing and practice in this case.
  3. At the time of this article, no standards have been developed for aerospace applications to define clearance and creepage distance.
  4. Industrial standards are relied on for distance estimations and must be verified through testing in high altitude conditions.

What are Creepage and Clearance Distances?

creepage/clearance
Clearance is the shortest distance between two conductive parts in air, whereas creepage is the minimum distance between two conductive parts along an insulating surface.

Clearance distance is the minimum separation distance between two conductive parts in air. This distance is based on the shortest line of sight between two conductive parts. Creepage distance is the minimum separation distance of two conductive parts along the surface of a solid insulating material.

Factors that Affect Creepage and Clearance

Voltage

When considering voltage, the system steady-state voltage is not enough to calculate creepage and clearance distances. The steady state peak voltage, recurring peak voltage, and any transients must be factored in to prevent any accidental flashover. Steady state peak voltage is defined as the maximum voltage that is typically associated with the steady state working voltage. The recurring peak voltage is the maximum voltage periodically seen from distortions in an AC power source when converted to a DC output. Transients are distinguished by being very short lived and heavily damped overvoltages.

Voltage Peaks
Steady state peak voltages, recurring peak voltages, and transients must all be considered in determining acceptable creepage and clearance distances.

Altitude

When altitude increases, pressure decreases and the susceptibility of air to breakdown increases until the pressure reaches near vacuum conditions. This follows the trend established in Paschen’s curve. As altitude increases, the susceptibility for partial discharge also increases, which can reduce the lifetime of EWIS components

Pollution

Creepage and clearance distance cannot be evaluated in the presence of pollution beyond a certain level. When the open-air environment or insulating surface is coated in dust and/or moisture, then a conductive path can be made, which can result in electrical shorting events. If the area is saturated in pollution, then the pollution acts as a medium for which electrons can flow between electrodes. Below this threshold, some standards do provide guidance on the impact that pollution can have on creepage and clearance.

Insulation Materials

The insulating material separating two circuits (or in the case of the accompanying images, holding the electrodes in place), will mostly affect creepage distance, although some consideration should be given to clearance if the insulating materials will influence field conditions. One common mode of evaluating an insulating material’s ability to withstand high voltage is the comparative tracking index test. This test is used to evaluate a material’s ability to withstand carbon tracking in the presence of a contaminant at relatively low voltage.

The topography of an insulating surface between electrodes can also influence the creepage distance. Use of barriers between electrodes can allow for shorter separation distances as the electric field is disrupted, causing a larger creepage distance.

Other Factors

If the generated electric field between two conductors is inhomogeneous, then the clearance must be increased by a larger separation distance than if the field was homogenous. An example of a homogenous field can be created by using oppositely charged parallel plates and an inhomogeneous field can be produced by similarly charged point-like conductors.

IEC 60664-1

The title for IEC 60664-1, “Insulation coordination for equipment within low-voltage supply systems,” is a bit counterintuitive since high voltage for aerospace as defined by the SAE AE-10 committee starts at 425VAC (600VDC). IEC 60664-1 is an industrial standard, which puts the low voltage threshold between 50VAC (120VDC) and 1000VAC (1500VDC). Below and above these voltages are classified as Extra Low Voltage and High Voltage respectively.

IEC 60664-1 will likely be heavily referenced in the corresponding SAE AE-10 ARP document as the standard has altitude corrections for up to 20000 meters (65617 feet).

Wrap Up

The opportunities that are made possible on aircraft with the use of high voltage systems are plenty. Of course, how the systems are deployed will be limited based on electrostatics and the material properties of the insulators. Both the creepage and clearance distance of EWIS components, particularly at connection points, will be a concept that every EWIS engineer will become familiar with. How the standards evolve to meet these challenges is still to be determined, but as the industry moves forward, Lectromec’s high voltage experience and testing capabilities will be ready to help. Contact us to find out how we can help your project.

Chris Wollbrink

Chris Wollbrink

Engineer, Lectromec

Chris has been with Lectromec since 2019 and has been a key contributor on projects involving testing of EWIS/fuel system failure modes, the impact of poor installation practices on EWIS longevity, and high voltage EWIS certification testing. His knowledge and attention to detail ensure consistent delivery of accurate test results from Lectromec’s lab.