2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Scrape Abrasion Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Aircraft wiring material considerations beyond insulators and conductors

Management

The basic tool kit to understand aircraft wiring goes beyond some of the basics. Here are some topics of interest:

Materials that are insulators

There are a large number of materials that are insulators and they can be either inorganic or organic. Practically all organic materials that are used for insulation purposes are polymers.

Inorganic materials

The insulating materials for aircraft wiring are almost always organic. The exceptions would be where fiber glass is used along with a polymer, e.g., with Poly (vinyl chloride) and silicon rubber. However, their usage is relatively limited currently in most aircraft. Also, inorganic fillers sometimes are used with a polymer. In some other wiring applications, ceramics are used for insulation.

Organic materials

As indicated above, organic wiring insulation used in aircraft is polymeric. The definition of a polymer is “a long molecule which contains a chain of atoms”.[i] This definition is very broad and encompasses living material that is life itself to highly sophisticated synthetic materials. The “chain of atoms” actually is composed of small groups of atoms that have a periodic structure that is repeated many times. While a few naturally occurring polymers are employed for insulation purposes, most insulating materials used today for wiring are synthetic. Organic polymers, due to their structure and composition, almost always are insulators, i.e., they have a band gap of approximately three or more eV- see the discussion below on the physical basis of insulators for details.

There are several classes of polymers that have been employed for wire insulation: hydrocarbons, halogenated polymers, nitrogen containing polymers, polyesters, silicones, cellulose, and varnish. The last two categories often are from natural sources. Only a selected few materials from the above classes have been used for wire insulation in aircraft. The reasons for this involve both specific chemical and physical properties of a material as it relates to aircraft usage. Such factors as weight, thickness, resistance to attack, both from chemical and physical sources, etc., are considered when choosing materials for aircraft wire insulation.  Other applications where electrical insulation is required make greater use of more common polymers. See the individual material pages for more information.

What is an insulator?

Perhaps the way to answer this question is to consider the difference between an insulator and conductor. One approach is to consider resistivity, which is defined as resistance to the passage of electrical current through a material. This quantity, in units of Ohm-cm or Ohm-m (keeping to MKS units) can vary well over twenty five orders of magnitude, e.g., some metals have a value of  approximately 10-8 Ohms-m to about 1017 Ohms-m for quartz. Semiconductors, e.g., silicon, have values that fall midway between those typical for conductors and insulators. This range of values is one of the largest for any physical material property.

If you are interested in more information on aircraft writing, you can read Lectromec’s Wire Flammability for Aircraft Wiring article.

aircraft wiring
Energy level diagram for an insulator or semi-conductor; the widths of the various levels are not scaled to actual energy values.

Another approach to describe an insulator is to examine the electronic structure of materials. The outermost electrons for an element (in terms of atomic structure) are in the valence band. These electrons participate in bonds with neighboring atoms in a material. Above the valence band is the conduction band. Nominally, there are no electrons in the conduction band. If the energy difference between the valence and conduction bands is zero, or even overlaps, then the material is a metallic conductor. In these instances, some electrons go easily between the valence band and the conduction band. However, if there is a definite energy difference between the valence and conduction bands, then electrons will not go between the two bands unless there is an external energy source. Note also that the electrons are forbidden to be between the valence and conduction bands if there is an energy difference. The usual unit to describe this energy difference (called the band gap) is the electron-Volt (eV)[ii]. For semiconductors, the band gap ranges from about 0.5 to 3 eV (this upper limit is not precise); the value for silicon, probably the most widely used semiconductor, is about 1.1 eV. The upper value for band gaps with insulating materials is approximately 9 eV. The figure above illustrates the energy levels for a semiconductor or insulator.


[i].  R. Y. Young, Introduction to Polymers, Chapman and Hall, New York, (1981) p1.

[ii]   1 eV equals 1.6 x 10-19 J.

Michael Traskos

This article was written by the Lectromec technical team. Aircraft wiring is our passion and we strive to make a contribution to the field by sharing our expertise through blogs, podcasts, and videos. We hope you find this information helpful. We also encourage you to submit comments and spur discussions.