2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Scrape Abrasion Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Solder Sleeves and Splicing in Shields

Testing & Assessment

Key Takeaways
  • To properly terminate shielded cables, the use of solder splices is sometimes needed.
  • There are a variety of solder splice options to address an application’s specific needs.
  • Solder splices go through a range of performance verification tests before qualification.

Shielded cables are necessary. They provide necessary EMI protection to ensure signal fidelity, and in some cables, such as coaxial cables, the shield is integral for signal transmission. Trying to use only non-shielded cables in any modern design would encounter such a significant impact on performance, it may not be possible except for a limited number of applications.

Because of this need for shielded cables, there is a wide range of components and supporting technologies to ensure proper use and reliable transmission of data. One of these technologies is a device to help with shield termination. Here, we review the need, use, and installation of solder sleeves.

Basics

If the cable’s shield were simply cut back and not terminated, this would leave a gap in the EMI protection creating an opportunity for electromagnetic noise to disrupt the signal integrity. Maintaining a continuous shield around the component conductors reduces the potential for EMI.

As a shielded cable arrive at connectors, if the connector is not designed for the termination of only that cable, it becomes vital for multiple cables to share the shielding to the connector shell. The shield termination at the connector becomes more complicated as the number of cables into a single connector increases (trying to properly terminate 10 shields at a single connector is not a trivial task). Solder sleeve products are designed to address the splicing and termination needs of shielded cables.

Installation

For installation, cable jacket is first stripped back to expose the shield. The length of this jacket removal is application dependent, but should be trimmed back enough that the shield and solder splice will not impact inserting component wires into the connector (this will likely be 1 – 5 inches depending on the number of wires into the connector and the connector size). The cable’s shield is then trimmed back away from the exposed cable end such that only a short segment of the shield remains exposed. The length of exposed shield will vary based on the cable size and solder sleeve combination and will range from 35 mils – 300 mils.

Using solder sleeves is a straight forward process that involves removing jacket, trimming back the shield, aligning the splice and applying heat.

The solder sleeve is then installed over the exposed jacket and shield. Here is where the magic of the solder sleeve comes in. The solder sleeve device itself is a heat-shrinkable thermoplastic sleeve that contains fluxed solder. When heated, the thermoplastic sealing ring at both ends of the splice contracts to provide an environmental seal. Furthermore, the thermoplastic sealing rings also act as strain relief on the solder sleeve – shield connection point by damping the impact of any cable flexing.

With further heating of the solder sleeve, the solder in the solder sleeve melts creating a bond with the cable shield. If the solder sleeve has a ground wire, the shield is now electrically bonded with the ground wire that can now be terminated to the connector backshell.

Types

There are several types of splices that fall under the AS83519 standard for heat-shrinkable solder type shield terminations. These include:

  • /1 that are supplied without a ground lead. This is so a solder sleeve can then have a ground wire added during installation. This device is classified as environmentally resistant. These also have a thermal indicator for indicating if sufficient heat has been applied to the solder-sleeve for the solder to wet and hopefully make a good connection with the ground wire.
  • /2 These are similar to the /1 type but they are supplied with a ground lead.
  • /3 These solder sleeves are supplied with a ground lead that is a shield braid. The shield braid enables improved termination in shielded harness applications. Whereas the ground wire from the /2 construction could be terminated in a connector contact, the shield braid is not intended for termination in contacts.
  • /4 These solder sleeves are designed to terminate multiconductor cables. The solder sleeve has multiple holes, one for each of the cable’s component wires. A nice feature of these solder sleeves is that not every hole has to be filled; when heat is applied, the thermoplastic will seal any unused hole.
  • /5 These are like the /2 but are ROHS compliant.

Testing

There are several tests that are defined in the AS8319 standard and may be employed as part of the solder sleeve’s qualification and quality assurance. These include:

  • Recovery of the Thermoplastic – verify that thermoplastic property contacts with the application of heat.
  • Longitudinal Change – verify the solder sleeve length does not change after the application of heat.
  • Copper Mirror Corrosion- verify the solder sleeve does not cause corrosion.
  • Voltage Drop – verify the millivolt drop across the sample is low.
  • Insulation Resistance – verify the solder sleeve’s thermoplastic seal.
  • Dielectric Withstand Voltage – verify the solder sleeve’s thermoplastic seal.
  • Tensile Strength – verify the quality of the solder sleeve – shield connection.
  • Altitude Immersion – verify performance under vacuum conditions.
  • Temperature Cycling – verify performance under thermal cycling conditions.
  • Moisture Resistance – verify performance when exposed to humid conditions.
  • Fluid Immersion – verify performance after exposure to common aerospace fluids.
  • Heat Aging – verify performance after high temperature exposure.
  • Flammability – verify meets aerospace flammability requirements.
  • Vibration – verify solder sleeve – shield electrical integrity after exposure to a vibrational environment.

As with any EWIS product, the individual specification sheets should be reviewed to ensure it matches the application requirements.

Installation Reminders

While many of the EWIS wires and cables now are rated for operation in temperatures at or over 200C, just like much of the supporting equipment, AS83519 shield terminations are only rated up to 150C. This does limit their use at lower temperature parts of the aircraft.

When using these devices, just like with other splices, it is important they, as much as possible, are staggered. Failure to do so can have multiple negative impacts which include:

  • A much larger wire harness that creates additional stress on the wires
  • Because the wire harness has a larger circumference, the wires exiting the splice are likely to be at a tighter angle
  • May no longer fit into clamps and require a larger clamp to be installed

Splicing in a Conclusion

The use of shielded cables requires the use of additional components to ensure their reliable installation. In the cases where additional termination solutions are needed, the use of solder sleeves can be considered. The AS83519 (or military version M83519) solder splices may be used for this application.

To ensure that you are using quality products is not easy. Lectromec’s ISO 17025 accredited lab can help with part performance verification, testing, and analysis. Contact us to find out more.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than a decade. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. Michael is an FAA DER with a delegated authority covering EWIS certification and the chairman of the SAE AE-8A EWIS installation committee.