2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Scrape Abrasion Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Finding wire faults/damage is not an easy task; Lectromec’s last two articles [here and here] went through several test methods in an attempt to detect damage on a coax cable, and even in lab conditions, the damage was not detectable.

Now consider that problem across an entire aircraft. In-situ testing of wires/cables has always been viewed as something of a challenge to the industry. Given the branching that most harnesses undergo, the various wire lengths, splices, and numerous termination conditions, it can be difficult. Attempts to automate some of the testing has come to the development of Automatic Wire Test Sets (AWTS [pronounced “Eh-Wits”]).

Because there are so many ways to test a wire harness, the US military sought to create a performance standard to cover the general ideas and best practices of this equipment. Here, we review the standard and some of the performance features that can be expected when using equipment in compliance with the standard.

The Specification

MIL-PRF-32070A (available on the DLA website) is the current revision of the “Performance Specification for Test Program Sets” managed by the Naval Air Warfare Center in Lakehurst NJ. In general, the document sets out a performance profile for the Test Program Sets (TPSs) that are, “a collection of hardware, software, and applicable documentation used for testing, fault detection and isolation, maintenance, and any other evaluations of components and equipment” [ Section 6.4.22].

Damaged Coax Cable
Wire diagnostic equipment should be able to identify equipment faults and point the user to a single fault location at least 95% of the time. The types of faults that can be found will vary between equipment. Be sure to pick one that matches your application needs.

How the test system performs the fault isolation is left entirely to the individual test set and the system under test, but must conform to several performance requirements including (not all encompassing):

  • Hooked up wire
  • Equipment footprint
  • Transportability

Identifying Faults

As part of the equipment’s performance testing the equipment must do the following:

[Section 3.3.6.4] The TPH performance test shall functionally test and evaluate the TPH (Test Program Hardware). If a failure is detected, the TP (Test Program) will halt any further testing, including UUT (Unit Under Test) testing. The TP shall direct the operator to execute the TPH diagnostics to effect repair of the TPH. At the completion of this test group, the TP shall return to the MAIN MENU. The TP shall:

  • A: contain modules that provide test segregation to allow verification of applicable TPH for testing a specific UUT with the UUT disconnected (for example, wraparound test using shorting plugs or cables).
  • B: have a run time interval not greater than ten minutes for each performance module and/or entry point.
  • C: detect 100 percent of detectable TPH faults, including faulty wire paths.
  • D: allow the ATE (Automated Test Equipment) operator to repeat/cycle each test or test sequence if more than one individual test is required to set up a test condition. A TPH GOOD message shall not result if a test is repeated due to a failed performance test.
  • E: be performed without removing TPH covers, using TPH extender boards, or probing of the TPH.
  • F. not require an additional interface device (ID).

Of course, the loaded statement is related to the detection of “100 percent of detectable TPH faults”. For wiring, the easy faults to detect are the hard shorts and open circuits, but what about corrosion on connector pins that increases the circuit resistance? Is this not a detectable fault? But therein lies the question between different types of equipment: How sensitive is the equipment as to not generate a false positive? This will vary based on the equipment and the setting of the equipment.

From a fault isolation perspective, within the range of the TPH capabilities, it must be able to fault isolate. The concept raised in the performance standard is that of ambiguity groups. This idea is the process of identifying the system fault that generated the fault message. Where possible, the equipment should be able to differentiate where the fault is (e.g. an issue with capacitor A versus capacitor B). The equipment is of little help if it identifies that there is a fault in the system without helping to troubleshoot where/what it is.

Implementation

When put into service, the TPH must be well designed. The MIL-PRF-32070A does place requirements on the workmanship of the final assembled product and includes the quality of soldering, wire routing, and harness/cable shielding requirements.One hinderance with implementation of much of this equipment is the time needed to build the specific test package (place what voltage/current on which pin and what the expected result should be), and the connection cables from the TPH to the UUT. It can be done, but it can be a time-consuming process.

Conclusion

The MIL-PRF-32070A places requirements on automated test equipment but does not place requirements on the types of faults or the sensitivity of the measurements – that is left to the individual application. As such, it is suggested that comparative testing be performed on any TPH prior to fielding a full suite as part of maintenance operations.

Further, it is important to remember what this equipment is: test equipment to help identify the current condition of the wiring – by its very nature it is not predictive. To get data to support predictive wiring system maintenance requires focused testing and analysis available from Lectromec. We have helped dozens of fleets get ahead of their wiring system maintenance needs saving millions of dollars of reworked and aircraft downtime.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than a decade. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. Michael is an FAA DER with a delegated authority covering EWIS certification and the chairman of the SAE AE-8A EWIS installation committee.