Wire & Cable Smoke Resistance

FOR: Wire FOR: Cable $880–$1,550

Available wire & cable smoke resistance methods for standards including AS4373, AS81044, AS85485 and others and samples such as Cable, Wire.

The smoke resistance test places a high current through the wire/cable to determines if the insulation/jacket will produce smoke. The current is increase on the specimen until the conductor temperature reaches the rated insulation temperature.

This test can be adjusted to examine the impact of wires/cables or secondary protection in the same harness. This of particular use for installed applications.

The following are some parameters that can be adjusted:

  • Target temperature
  • Test duration
  • Enclosure temperature
  • Other wires/cables in harness or secondary harness protection

Choose the exact method

4 offerings

Pricing and sample requirements vary by test method. Specific test requirements can be added on the request quote page. Final scope and pricing are confirmed by Lectromec usually within 24 hours.

LEC-TST-000235

Smoke Resistance (Current to Smoke)

AS4373 · 513

Sample type
Cable
Specimens per test
1
Length per test
180 in
$1,550 for one; $730 each additional
LEC-TST-000461

Smoke Resistance

AS81044 · 4.7.5.24

Sample type
Wire
Specimens per test
1
Length per test
180 in
$1,550 for one; $730 each additional
LEC-TST-000487

Smoke

AS85485 · 5.23

Sample type
Cable
Specimens per test
1
Length per test
225 in
$880 for one; $260 each additional
LEC-TST-001683

Smoke

MIL-STD-2223 · 4008

Sample type
Wire
Specimens per test
1
Length per test
150 in
$950 for one; $400 each additional