Wire & Cable Jacket Flaws Spark Test
FOR: Wire FOR: Cable From $540; some methods require a quoteAvailable wire & cable jacket flaws spark test methods for standards including ANSI WC27500 NEMA WC27500, AS22759, AS4373 and others and samples such as Cable, Wire.
The jacket flaws test (spark test, insulation-continuity proof test, or insulation faults test) aims to identify any defects in a wire/ cable’s outer insulation that would allow an amount of leakage current. Testing is performed in an enclosure filled with conductive metal beads/ balls. The beads are electrified and connected to a continuity detection circuit along with the conductor of the sample under test. The sample is fed through the enclosure such that it is constantly surrounded by the electrified metallic beads.
A quality insulator/ jacket will prevent continuity between the sample conductor and the electrified beads. If continuity is detected in the circuit twice in the same location along the length of the sample, it is considered a failure. The total number of failures (if any) are reported.
Choose the exact method
Pricing and sample requirements vary by test method. Specific test requirements can be added on the request quote page. Final scope and pricing are confirmed by Lectromec usually within 24 hours.
Jacket Flaws
ANSI WC27500 NEMA WC27500 · 4.3.04
- Sample type
- Cable
- Specimens per test
- 1
Finished Wire Insulation Flaws
AS22759 · 4.5.6
- Sample type
- Wire
Spark Test of Finished Wire Insulation
AS4373 · 505
- Sample type
- Cable
Spark Test
AS6070 · 5.2.17
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 240 in
Spark Test
AS6070 · 5.2.17
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 240 in
Flaws Test of Primary Insulation
AS81044 · 4.7.4
- Sample type
- Wire
Insulation Flaws
AS81044 · 4.7.5.01
- Sample type
- Wire
Spark Test of Component Insulation or Cable Jacket
AS85485 · 5.18
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 360 in
Insulation - Continuity Proof Test
ASTM D3032 · 13
- Sample type
- Wire
Insulation Flaws
FED-STD-228 · 6211
- Sample type
- Wire
Spark Test
ICEA T-27-581 NEMA WC 53-2008 · 2.02.4
- Sample type
- Cable
Spark Test
J1654 · 5.2
- Sample type
- Cable
Spark Test
MIL-DTL-17 · 4.8.03
- Sample type
- Cable
Jacket Flaws
MIL-DTL-24643D · 4.9.09
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 240 in
Insulation Flaws
MIL-DTL-25038 · 4.6.13
- Sample type
- Wire
- Specimens per test
- 1
Insulation flaws
MIL-DTL-49055G · 4.7.3
- Sample type
- Cable
Cable Jacket Spark Test
MIL-STD-2223 · 3002
- Sample type
- Wire
- Specimens per test
- 1
Spark Test
MIL-W-81822 · 4.6.17
- Sample type
- Wire
- Specimens per test
- 0
Spark Test
SAE J2031 · 4.01
- Sample type
- Cable
Spark Test Method
UL-1581 · 900
- Sample type
- Wire
Spark Tests for Power-Limited Circuit Cable and Fire-Alarm Circuits
UL-1581 · 910
- Sample type
- Wire
Catalog data generated from Lectromec's controlled Box workbook, version
2655261484000. Internal costing and supplier identities
are not published.