Wire & Cable Concentricity Wall Thickness

FOR: Wire FOR: Cable From $200; some methods require a quote

Available wire & cable concentricity wall thickness methods for standards including ANSI WC27500 NEMA WC27500, AS22759, AS4373 and others and samples such as Cable, Wire.

Measuring the insulation concentricity and wall thickness is a quality assurance test that can identify uniformity issues. Wires with non-uniform insulation (or cables with non-uniform jackets) will have an unbalanced insulation wall thickness that can make the wire/cable more susceptible to mechanical or electrical failure. This test can be performed on wire gauges ranging from 30AWG to 0000AWG and on wholly tape wrapped and extruded constructions.

Choose the exact method

18 offerings

Pricing and sample requirements vary by test method. Specific test requirements can be added on the request quote page. Final scope and pricing are confirmed by Lectromec usually within 24 hours.

LEC-TST-000044

Jacket Wall Thickness

ANSI WC27500 NEMA WC27500 · 4.3.12

Sample type
Cable
Specimens per test
1
Length per test
12 in
$610 for one; $260 each additional
LEC-TST-000048

Concentricity

ANSI WC27500 NEMA WC27500 · 4.3.16

Sample type
Cable
Specimens per test
1
Length per test
12 in
$630 for one; $260 each additional
LEC-TST-000091

Insulation Concentricity and Wall Thickness

AS22759 · 5.5.5

Sample type
Wire
Specimens per test
1
Length per test
12 in
$770 for one; $400 each additional
LEC-TST-000190

Concentricity and Wall Thickness

AS4373 · 101

Sample type
Cable
Specimens per test
1
Length per test
6 in
$320 for one; $130 each additional
LEC-TST-000447

Insulation Thickness

AS81044 · 4.7.5.09

Sample type
Wire
Specimens per test
1
Length per test
6 in
$320 for one; $130 each additional
LEC-TST-000448

Concentricity

AS81044 · 4.7.5.10

Sample type
Wire
Specimens per test
1
Length per test
6 in
$320 for one; $130 each additional
LEC-TST-000471

Concentricity and Wall Thickness

AS85485 · 5.7

Sample type
Cable
Specimens per test
1
Length per test
6 in
$320 for one; $130 each additional
LEC-TST-000583

Concentricity

ASTM D3032 · 15

Sample type
Wire
$480 for one; $90 each additional
LEC-TST-001014

Concentricity

ICEA S-121-733 · 6.9

Sample type
Cable
Specimens per test
1
Length per test
12 in
$700 for one; $350 each additional
LEC-TST-000974

Thickness of Insulation

ICEA S-81-570 · 3.2

Sample type
Cable
Specimens per test
1
Length per test
12 in
$200 for one; $70 each additional
LEC-TST-000939

Neutral Insulation Thickness

ICEA T-27-581 NEMA WC 53-2008 · 3.5.2

Sample type
Cable
Specimens per test
1
Length per test
12 in
$300 for one; $150 each additional
LEC-TST-001050

Thickness of Thermoplastic and Elastomeric Insulation and Sheath

IS 10810 · 6

Sample type
Cable
Specimens per test
1
Length per test
60 in
$320 for one; $160 each additional
LEC-TST-001063

Insulation Thickness

ISO 6722-2011 · 5.2

Sample type
Cable
Contact Lectromec for pricing
LEC-TST-001318

Concentricity

MIL-DTL-25038 · 4.6.2

Sample type
Wire
$770 for one; $400 each additional
LEC-TST-001319

Concentricity

MIL-DTL-25038 · 4.6.2

Sample type
Wire
$400 for one; $210 each additional
LEC-TST-001735

Concentricity of Insulation

MIL-W-81822 · 4.6.13

Sample type
Wire
Contact Lectromec for pricing
LEC-TST-001771

Thickness of Covering

NEMA WC 57 · 6.11

Sample type
Cable
Specimens per test
2
Length per test
5 in
$300 for one; $140 each additional
LEC-TST-001772

Elongation of Jacket

NEMA WC 57 · 6.7

Sample type
Cable
Specimens per test
5
Length per test
6 in
$420 for one; $140 each additional