2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector Connector Durability Connector Failure Modes connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Firewall Fixturing Flame Resistance Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Scrape Abrasion Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Archives

Wet Arc Propagation Resistance (European Method)

The wet arc-resistance test for wire insulation provides an assessment of the ability of an insulation to prevent damage in an electrical arc environment. In service, electrical arcs may originate from a variety of factors including insulation deterioration, faulty installation, and chafing. It has been documented that results of an arc-propagation test may vary slightly […] Read more

Conductor Stranding 

The lay of conductor stands in a wire conductor has a significant impact on a wire’s performance. In particular, wires with stranded conductors tend to have greater flexibility than those with single core conductors. The conductor stranding test it is a quality check to evaluate the conductor stranding. The individual strands of the conductor are […] Read more

Electrolytic Erosion

Whether through contamination during maintenance actions, ingress from degraded seals, or other degradation, the fluid ingress into a connector can cause degradation and impact reliability. To assess this, the electrolytic erosion test measures the propensity of connectors to erode when contaminants are present and the connector is in use. The test consists of introducing a […] Read more

Plating Adhesion

Composite connectors (Class J and M) provide the benefit of a lightweight construction with limited drawbacks. To verify the connector plating in high temperature operation conditions, the plating adhesion test is performed. For this test, the connector under evaluation is immersed in oil at its operational temperature.  It is then quickly cooled to room temperature […] Read more

Post Test Examination

The post test examination is a visual assessment commonly used after stressing the sample connector. This is an encompassing visual examination of physical nonconformities and possible effects of previously applied testing. This test is typically performed without the aid of magnification. Read more

Temperature Cycling

Connectors are cycled between a low temperature and high temperature environment, and the plating is examined. This is an examination to ensure that after temperature changes connectors do not display signs of peeling, blistering, flaking, and separation of plating or other damage detrimental to the operation of the connector. Read more

Ice Resistance

Through the service life of an aircraft there are thousands of electrical thermal cycles. Those connectors subjected to external conditions maybe become icy during flight. This ice resistance test examines a connector’s performance in icy conditions. In the test, mated connectors are immersed in water and then frozen to -65C for three cycles. At the […] Read more

Contact Engagement and Separating Force

The engagement force of a connector contact is an indicator of whether a good electrical connection is made. This test examines the contact engagement forces. For female type connectors, each socket is tested individually by using a male connector with only one pin installed in the appropriate position to mate with the socket under test. […] Read more

High Temperature Exposure with Contact Loading

For this test, contacts are removed and crimped to a wire and then reinstalled. An initial measurement of the axial location is made with a 2-pound axial load, a specified weight is suspended freely from the contact, and a monitoring circuit connected that senses discontinuities. The connectors are then placed within an oven at elevated […] Read more

Contact Walkout

For this test, a pin installed in the connector is crimped to a wire, and the wire is hung over a mandrel with a weight.  The connector position relative to the mandrel then undergoes one hundred cycles, effectively stressing the installed pin. Two pins are tested per connector, and the pins in question must not […] Read more