Contamination
The contamination test measures the quality factor (Q) of a test sample. The specimen length for the contamination test ranges between 2-4 feet of PVC type jacket, depending upon the diameter of the cable being tested. One end of the specimen is cut square, while the other end is prepared to provide the shortest possible […] Read more