Section 6.3 (temperature variant) of SAE J1128 defines mechanical property tests at elevated temperature for primary wire insulation. This variant evaluates how insulation mechanical properties are affected by temperature.
Testing at elevated temperature provides data on insulation performance under conditions that simulate in-service exposure near heat sources in automotive wiring applications.