Insulation Volume Resistivity

The insulation volume resistance test verifies that the amount of leakage current from a wire sample is within the acceptable range for a particular application by determining the resistivity of the insulation sample.

The test sample is submerged in a tap water bath within 250mm of each end. A DC voltage is applied between the water bath and the test sample for one minute, and the insulation resistance is measured. Measurements are used to calculate the insulation volume resistivity.

Covered specifications

  • AMS 8660 Method 4.6.11
  • AS23053 Method 5.2
  • ASTM D876 Method 52-57
  • ISO 19642-2 Method 5.2.6
  • J1127 Method 6.10
  • J1128 Method 6.15
  • MIL-M-24041 Method 4.7.44
  • ISO 6722 Method 5.7
  • AS23053 Rev A Method 5.02
  • AS85485 Method 5.1
  • J1128 Method 6.16