Cable Thermal Endurance
FOR: Cable $1,520–$20,740Available cable thermal endurance methods for standards including AS4373, EN3475 and samples such as Cable.
The thermal endurance (or high temperature endurance) test determines the ability of the insulation of a firezone or similar wire to resist degradation due to exposure to high temperature. Degradation is judged by change in conductor resistance, cracking during bending, insulation dielectric breakdown, or decreased resistance to fluids. All of these points shall be tested by using 3 foot long samples from the wire specimen after the heat exposure.
Choose the exact method
Pricing and sample requirements vary by test method. Specific test requirements can be added on the request quote page. Final scope and pricing are confirmed by Lectromec usually within 24 hours.
High Temperature Endurance
AS4373 · 814
- Sample type
- Cable
- Specimens per test
- 1
- Length per test
- 48 in
Thermal Endurance
EN3475 · 410
- Sample type
- Cable
- Specimens per test
- 2
- Length per test
- 60 in
Catalog data generated from Lectromec's controlled Box workbook, version
2655261484000. Internal costing and supplier identities