2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

To Shield or Not to Shield – A Question on High Voltage DC Cables

Protection & Prevention

Key Takeaways
  • Shielding on aerospace cables offers several benefits but can introduce some drawbacks that must be considered.
  • A Cable shielding’s primary purpose is to limit the impact of radiated energy on the cable itself or other nearby systems, making it essential to consider for modern-day high-voltage (HV) aircraft.
  • Cable shielding negatively affects the weight, flexibility, physical complexity, and diameter of a cable all of which may impact EWIS design and installation.

The high electrical power needs of aircraft have resulted in the design, development, and testing of a wide range of new components. While many of the EWIS design patterns remain the same, changes in EMI sensitivity of electrical equipment have also pushed changes in where and how EWIS is deployed in the aircraft. One of the most common tradeoffs EWIS engineers must undertake is the extent of shielded is used in the EWIS. Lectromec has touched on this topic before, but this article specifically considers the needs of all electrical hybrid aircraft high-voltage power feeder cables and the use of cable shielding.

Background

A Cable shielding’s primary purpose is to limit the impact of radiated energy on the cable itself or other nearby systems. Traditional aircraft design has been to select unshielded cables for the power feeders and shield only those cables connected to sensitive circuits. This limited the shielding to smaller cables usually with conductors sized 20 – 26 AWG.

With different system needs and performance requirements, the EWIS design patterns have needed reassessment to achieve optimal design and reassess generally accepted assumptions on balancing performance with conservative design techniques. The following are several high-level factors for and against using shielded high-voltage power cables.

Pros

The consideration of shielding for HV cables is for the following reasons:

Magnetic field protection: Depending on the location of the cable routing in the aircraft (if it is high powered and near crew or passengers) health concerns may exist. Cable shielding helps to reduce the magnetic field strength thus reducing the potential health concerns.

Switching: Depending on the power system configuration, the EMC (Electromagnetic Compatibility) impact of the high-voltage DC distribution system might be minimal, but once converted to alternating current for the propulsion system, the high-frequency switching of the power can be a major source of EMI (Electromagnetic Interference). How the switching system is designed will also impact the generated EMI. A shielded cable, braided or foil-wrapped, can help to reduce this impact

Separation Distance: The addition of cable shielding may help to reduce the required separation distance between the power and signal cables. This can be in two ways: EMI protection and arc damage. From an arc damage perspective, a cable shield can either act to support the continuation of the arcing event (if electrically connected to the power system through a common ground) or help to slow the progression of the arcing event. If not electrically connected, the shield is a layer of metal that must either be damaged or destroyed by the arc’s thermal energy; this is a significantly less effective method for metal destruction than direct electrical arcing. It is because of this that the shield can act as a barrier and help to reduce separation distances.

Fault detection: Adding a shield to the cable provides a means to detect if there is a fault in the high-voltage wire insulation. This might be a direct shorting event to the shield (likely near a termination point) or, for high-sensitivity systems, this could also be a mechanism for partial discharge detection. The capability to detect and isolate these types of faults does not remove the additional burden of sensors and monitoring equipment, but as the high-voltage parts of EWIS evolve, this could become a critical part of a health and monitoring system. In particular, this could be part of flight testing of new platforms that do not have the historical data to determine part longevity.

Additional Protection Layer: The shielding also means that there will likely be a jacket on the cable. Given the potential impact of a high-voltage wire fault, it is beneficial to have additional physical barriers to limit damage. From a scrape abrasion and notch cut perspective, adding a jacket and shield can dramatically increase the protection from mechanical damage.

Shielded Cable
Construction of a shielded cable.

Cons

The use of shielding does have disadvantages that should not be ignored.

Cost: The additional cost of cable shielding is not insignificant and should be considered as part of the engineering tradeoffs for use. The optical coverage, type of shielding, and design (round conductors versus flat conductors) all have an impact and need evaluation.

Flexibility: Shielded cables increase the resistance to mechanical flexing. Even under ideal designs with small gauge, high strand count shielding, a shielded cable requires more force to bend than a non-shielded wire. This impacts the product’s workability as well as performance in flexing applications.

Weight: In the aerospace industry, additional weight is often viewed as the greatest negative for any product. Shielding does add weight to any cable and the amount of extra weight is based on several factors including cable size, coverage, type of conductor used for shielding, etc.. Using that as a starting point, if there is not a justification for the use of a shielded cable (and the arguments for shielding earlier in the article were not persuasive enough), then the additional shielding weight should be sufficient reason to avoid the use of the cable shielding.

Diameter: The addition of cable shielding and jacketing does not add too much to the cable diameter, but if there are tight spaces in the aircraft (feedthroughs, conduits, etc.) where space is limited, the additional cable diameter is noticed.

Maintainability: Shielded cables take more effort and more tooling to repair. When considering high-voltage cable repair, this also requires that all of the components used for the repair are rated for high-voltage use and can provide the same performance and protection as the original part.

Ground Plane for PD (Partial Discharge): If the cable shield is connected to the electrical circuit (typically as a ground), then there is a voltage gradient across the wire insulation that provides potential locations for partial discharge. Without a shield, the opportunities for PD from the HV wire become more limited. Of course, by selecting a cable with a high PDIV/PDEV across the entire operational profile of the vehicle, PD can be avoided in most cases.

Conclusion

EWIS design is no longer as simple as picking a qualified wire/cable and installing it anywhere in the aircraft; the performance requirements of high-voltage aircraft now require greater attention to detail. The pros of using a shielded high-voltage cable should provide sufficient justification in many cases for their use and should probably be the default for most applications. With shielded high-voltage cables as the default, an analysis must then be done to justify using un-shielded high-voltage cables; the expectation is the analysis will go beyond a simple statement of “because it weighs less” and more deeply consider the aircraft level impacts.

If you are looking for support for your high-voltage EWIS analysis, testing, or certification, contact Lectromec. We have been supporting high-voltage EWIS development when it was still in the fundamental research stage and can help you with your current development needs.

Michael Traskos

Michael Traskos

President, Lectromec

Michael has been involved in wire degradation and failure assessments for more than two decades. He has worked on dozens of projects assessing the reliability and qualification of EWIS components. Michael is an FAA DER with a delegated authority covering EWIS certification and the former chairman of the SAE AE-8A EWIS installation committee.