2021 25.1701 25.1703 abrasion AC 33.4-3 AC 43 Accelerated Aging accessibility ADMT Aging Systems AIR6808 AIR7502 Aircraft Power System aircraft safety Aircraft Service Life Extension Program (SLEP) altitude Aluminum arc damage Arc Damage Modeling Tool Arc Fault (AF) Arc Fault Circuit Breaker (AFCB) Arc Resistance Arc Track Resistance Arcing Arcing Damage AS22759 AS22759/87 AS23053 AS29606 AS4373 AS4373 Method 704 AS50881 AS5692 AS6019 AS6324 AS81824 AS83519 AS85049 AS85485 AS85485 Wire Standard ASTM B230 ASTM B355 ASTM B470 ASTM D150 ASTM D2671 ASTM D495 ASTM D8355 ASTM D876 ASTM F2639 ASTM F2696 ASTM F2799 ASTM F3230 ASTM F3309 ATSRAC Attenuation Automated Wire Testing System (AWTS) Automotive Avionics backshell batteries bend radius Bent Pin Analysis Best of Lectromec Best Practice bonding Cable Cable Bend cable testing Carbon Nanotube (CNT) Certification cfr 25.1717 Chafing Chemical Testing Circuit Breaker circuit design Circuit Protection cleaning clearance Coaxial cable cold bend collision comparative analysis Compliance Component Selection Condition Based Maintenance Conductor Conductor Testing conductors conduit Connector connector installation Connector rating connector selection connector testing connectors contacts Corona Corrosion Corrosion Preventing Compound (CPC) corrosion prevention Cracking creepage D-sub data analysis data cables degradat Degradation Delamination Derating design safety development diagnostic Dielectric breakdown dielectric constant Dimensional Life disinfectant Distributed Power System DO-160 dry arc dynamic cut through E-CFR electric aircraft Electrical Aircraft Electrical Component Electrical Power Electrical Testing Electrified Vehicles Electromagnetic Interference (EMI) Electromagnetic Vulnerability (EMV) Electrostatic Discharge EMC EMF EMI EN2235 EN3197 EN3475 EN6059 End of Service Life End of Year Energy Storage engines Environmental Environmental Cycling environmental stress ethernet eVTOL EWIS certification EWIS Component EWIS Design EWIS Failure EWIS sustainment EWIS Thermal Management EZAP FAA FAA AC 25.27 FAA AC 25.981-1C FAA Meeting failure conditions Failure Database Failure Modes and Effects Analysis (FMEA) FAQs FAR FAR 25.1703 FAR 25.1707 FAR 25.1709 Fault fault tree Filter Line Cable Fixturing Flammability fleet reliability Flex Testing fluid exposure Fluid Immersion Forced Hydrolysis fuel system fuel tank ignition Functional Hazard Assessment functional testing Fundamental Articles Fuse Future Tech galvanic corrosion Glycol Gold Gold plating Green Taxiing Grounding hand sanitizer handbook Harness Design harness protection hazard Hazard Analysis health monitoring heat shrink heat shrink tubing high current high Frequency high speed data cable High Voltage High Voltage Degradation HIRF History Hot Stamping Humidity Variation HV connector HV system ICAs IEC 60851 IEC60172 IEEE immersion insertion loss Inspection installation installation safety Instructions for Continued Airworthiness insulating material insulating tape Insulation insulation breakdown insulation resistance insulation testing interchangeability IPC-D-620 ISO 17025 Certified Lab ISO 9000 J1673 Kapton Laser Marking life limit life limited parts Life prediction life projection Lightning lightning protection liquid nitrogen lithium battery lunar Magnet wire maintainability Maintenance Maintenance costs Mandrel mean free path measurement mechanical stress Mechanical Testing MECSIP MIL-C-38999 MIL-C-85485 MIL-DTL-17 MIL-DTL-23053E MIL-DTL-3885G MIL-DTL-38999 MIL-E-25499 MIL-F-5372 MIL-HDBK MIL-HDBK-1646 MIL-HDBK-217 MIL-HDBK-454 MIL-HDBK-516 MIL-HDBK-522 MIL-HDBK-525 MIL-HDBK-683 MIL-STD-1353 MIL-STD-1560 MIL-STD-1798 MIL-STD-464 MIL-T-7928 MIL-T-7928/5 MIL-T-81490 MIL-W-22759/87 MIL-W-5088 MIL–STD–5088 Military 5088 modeling moon MS3320 NASA NEMA27500 Nickel nickel plating No Fault Found OEM off gassing Outgassing Over current Overheating of Wire Harness Parallel Arcing part selection Partial Discharge partial discharge at altitude Performance physical hazard assessment Physical Testing polyamide polyimdie Polyimide-PTFE Power over Ethernet power system Power systems predictive maintenance Presentation Preventative Maintenance Program Probability of Failure Product Quality PTFE pull through Radiation Red Plague Corrosion Reduction of Hazardous Substances (RoHS) regulations relays Reliability Research Resistance Revision C Rewiring Project Risk Assessment S&T Meeting SAE SAE Committee Sanitizing Fluids Scrape Abrasion Secondary Harness Protection separation separation distance Separation Requirements Series Arcing Service Life Extension Severe Wind and Moisture-Prone (SWAMP) Severity of Failure shelf life Shield Shielding Shrinkage signal signal cable Silver silver plated wire silver-plating skin depth skin effect Small aircraft smoke Solid State Circuit Breaker Space Certified Wires Splice standards Storage stored energy superconductor supportability Sustainment System Voltage Temperature Rating Temperature Variation Test methods Test Pricing Testing testing standard Thermal Circuit Breaker Thermal Endurance Thermal Index Thermal Runaway Thermal Shock Thermal Testing tin Tin plated conductors tin plating tin solder tin whiskering tin whiskers top 5 Transient Troubleshooting TWA800 UAVs UL94 USAF validation verification video Visual Inspection voltage voltage differential Voltage Tolerance volume resistivity vw-1 wet arc white paper whitelisting Winding wire Wire Ampacity Wire Bend Wire Certification Wire Comparison wire damage wire failure wire performance wire properties Wire System wire testing Wire Verification wiring components work unit code

Aircraft wire failure and incident investigation, Part I

Arcing

The hazard of aircraft wire failure and electrical arcing will exist for as long as there is a need to deliver electrical power through wires. While electrical arcing is a common occurrence, the factors that impact an arcing event are often not well understood. This article reviews each step involved in electrical arcing, from what initiates it to its effects on the system.

Precondition to Arcing

For arcing to occur, it is necessary that some portion of the circuit wiring be exposed. This article will focus on wiring and not failure at connection points.

There are a number of mechanisms that can create the preconditions for an arcing event to occur:

1. Age related degradation of the wire insulation

Degraded/aged wire insulation may result in radial cracks to the conductor.

2. Overheated Circuit

Overheated circuits (or wire bundles) can melt the insulation and expose the conductor.

3. Fluid Exposure

Some wire insulations degrade very quickly when exposed to certain fluids.

4. Error in manufacturing

The finished wire product has breaches in the insulation.

5. Damage during Installation or maintenance

Working with wiring harnesses can result in damage to the insulation

6. Abrasion

A bundle that is not properly secured can sway and rub against structures or components. There are other mechanisms that lead to wire insulation damage, but they are typically subsets of the mechanisms listed above.

wire failure
An arcing event can completely sever a wire

The Arc Begins

Once the power wire has been damaged to a point where the conductor is exposed and there is a low resistance path to a different potential, arcing can begin. This different potential can be a grounded object (such as a component, structure, or a ground wire) or another power wire on a different phase.

Electrical Arcing

Once the arcing starts, the destruction of insulation and conductor immediately begins. These materials are often released into the immediate atmosphere and become part of the arc plume. The arc plume is a hot ionized gas that provides a low resistance path for the electrical arcing. Furthermore, this plume expands out from the arcing event and can damage nearby objects.

Electrical Arc Parameters

There are only a few parameters that directly affect the electrical arc and its progression. These include:

1. Distance from the power source

This affects the fault current and energy available for arcing.

2. Wire type

Some insulations have a propensity to limit the arc damage, but none can fully eliminate the damage from an arcing event

3. Circuit protection

Depending on the type and rating, this will determine the arc duration

4. Number of power/ground wires in bundle

The initial arcing event can result in the damage to other wires in the bundle and bring those wires into the arcing event.

Arc Termination Conditions

After the arc starts, there are only a few mechanisms that can halt the arcing event. The first one is the activation (tripping) of the circuit breaker. Depending on the type of the circuit breaker and the fault current, this might trip quickly or take several seconds before it opens. The other mechanism for ending an active arcing event is increasing the separation between the two conductors (or conductor and ground). The separation distance necessary is dependent on the voltage and the duration of arcing event.

Parameters Affecting Damage

Aside from the arcing event, it is necessary to consider the parameters that affect the damage level. These include:

1. Target materials

The structure or component material can impact the duration of the arc as well as the extent of the damage.

2. Tube pressurization

Different pressure levels can impact heat transfer and subsequent damage to pressurized tubes.

3. Contamination

Dirt, debris, and fluids can impact how much damage is done. These can either ignite and cause additional damage or limit the impact.

4. Separation distance and segregation materials

The physical separation distance impacts how much energy or direct arcing can impact the object. Furthermore, segregation materials (such as wire harnesses sleeves) also impact the damage level.

Possible Effects of Arcing

While this is the last part of the electrical arcing event, this is probably the most important part to consider. After all, if the wire arcs and has no negative impact on a system, it does not matter. But more often than not, an arcing wire will cause physical and/or functional damage. A functional damage can lead to un-commanded activation of devices or systems by transferring energy to other circuits or can result in loss of system functionality. A physical damage can mean damage to structure, to other wires in a bundle, or even damage and breach of hydraulic/fuel lines. The level of severity varies depending on the type of damage and can only be assessed through a full risk assessment of the wiring system. This risk assessment must combine the consequence of failure with the probability of failure. This is possible with tools such as Lectromec’s EWIS RAT (Electrical Wire Interconnection Systems Risk Assessment Tool).

Michael Traskos

Michael Traskos

President, Lectromec