This test establishes the thermal endurance rating of connector by subjecting specimens to extended aging at multiple elevated temperatures as specified in EN2591. The time to failure at each temperature is recorded, and Arrhenius analysis is used to extrapolate a thermal index or temperature rating.
Thermal endurance testing provides the scientific basis for establishing temperature ratings and expected service life of insulation materials. The test typically requires thousands of hours of aging at multiple temperatures.